Westdc Logo

Observation on Soil Moisture of Irrigation Cropland by Cosmic-Ray Probe


作者


摘要

The newly developed cosmic-ray probe (CRP) method for measuring area-average soil moisture at the hectometer horizontal scale was tested in the 2012 observation campaign of the Heihe Watershed Allied Telemetry Experimental Research (HiWATER) in the irrigated cropland area of Zhangye Oasis. As compared with the traditional point observation, data analysis shows that the CRP could measure the real areal soil moisture, except when the water is frozen and during thaw. During the irrigation period, the presence of surface water can lead to an overestimation of the soil moisture. During non-irrigated periods, the CRP has a very strong correlation with the averaged soil moisture of 19 SoilNET probes in its footprint, whose R2 is 0.73 and root-mean-square error is 0.0275 m3/m3. In comparison with the Polarimetric L-band Multi-beam Radiometer (PLMR) retrieved soil moisture, which has a pixel resolution of 700 m, the CRP provides much better results, with a coefficient of determination of 0.96 and 0.64, respectively. The results show that the CRP is a robust area-averaged soil moisture observation method, which can be used to obtain “true” values of field-scale soil moisture for remote sensing validation.


关键词

  • AD 2012
  • area-averaged soil moisture observation method
  • area-average soil moisture measurement
  • averaged soil moisture very strong correlation
  • Cosmic-ray probe (CRP)
  • cosmic-ray probe method
  • CRP method
  • data analysis
  • determination coefficient
  • field-scale soil moisture true value
  • frozen water
  • hectometer horizontal scale
  • Heihe Watershed Allied Telemetry Experimental Research
  • Heihe Watershed Allied Telemetry Experimental Research (HiWATER)
  • HiWATER observation campaign
  • irrigation
  • irrigation cropland area
  • irrigation period
  • Moisture measurement
  • Neutrons
  • nonirrigated period
  • pixel resolution
  • PLMR retrieved soil moisture
  • Polarimetric L-band Multibeam Radiometer
  • Probes
  • radar polarimetry
  • radiometers
  • real areal soil moisture measurement
  • Remote sensing
  • remote sensing validation
  • root-mean-square error
  • soil
  • Soil measurements
  • soil moisture
  • soil moisture observation
  • soil moisture overestimation
  • SoilNET probe
  • surface water
  • traditional point observation
  • vegetation mapping
  • water resources
  • wireless sensor network
  • Zhangye oasis

引用方式

Zhu ZL, Tan L, Gao SG, Jiao QS. Oberservation on soil moisture of irrigated cropland by cosmic-ray probe. IEEE Geoscience and Remote Sensing Letters, 2015, 12(3), 472-476.

PDF下载 RIS下载 相关数据(共条)